High Flow Rate 4 Inch Diaphragm WPS-CA/EP102 For Solenoid Pulse Valve Application Dedusting

Brand Name : OEM

Model Number : WPS-CA/EP102

Certification : ISO、CE

Place of Origin : China

MOQ : 1Pcs,Sample Available

Price : negotiation

Payment Terms : L/C, T/T, Western Union

Supply Ability : 100000pcs per month

Delivery Time : 7 working days

Packaging Details : PVC bag, inner box, carton, than packed by pallet; also can be packed by color card and can be customized

Material : NBR

Power : Pneumatic

Color : Black

Size : Standard or Customer Demand

Temperature : -50℃~+2800℃(depends rubber materials)

Application : Dedusting

Contact Now

High Flow Rate 4 Inch Diaphragm WPS-CA/EP102 for Solenoid Pulse Valve Application Dedusting

Electromagnetic pulse valve diaphragm makes the whole dust collector failure: because a valve diaphragm rupture, will lead to a large reduction in the pressure of the whole air bag and insufficient air volume, make the other valve on the air bag can not normally spray. The dust removal of the dust remover is not good, will produce local paste bag phenomenon, the dust remover air cloth ratio increases, the operation resistance increases, speeds up the shortening filter material working life.

The electromagnetic pulse valve diaphragm produced by the company is imported and improved by the international advanced design technology, which is used for the compressed air switch dust removal of the dust collector dust removal system.

Name WATSON Pulse Valve Diaphragm
Model WPS-CA/EP102
Material Nitrile Rubber
Hole number for mounting 8
Working temperature depands rubber materials
Working pressure 0.2Mpa-0.6Mpa
Working medium Water, Clean Air
Diaphragm working life More than 1 million cycles

The other 4 Inch Big Diaphragms are also can be available

High Flow Rate 4 Inch Diaphragm WPS-CA/EP102 For Solenoid Pulse Valve Application Dedusting High Flow Rate 4 Inch Diaphragm WPS-CA/EP102 For Solenoid Pulse Valve Application DedustingHigh Flow Rate 4 Inch Diaphragm WPS-CA/EP102 For Solenoid Pulse Valve Application Dedusting

Are there air holes on the side and in the middle of the pulse valve diaphragm?

Select pulse valve diaphragm can not simply look at membrane pores in what position, but also look to and supporting the use of pulse valve diaphragm in porosity in what position, if the pulse valve in stomata in the edge edge will use in porosity of the diaphragm to match, if there is no loophole edge of pulse valve should be used with porosity of diaphragm, if you don't corresponding pulse valve and the membrane pores, can cause air flow is not smooth, pulse valve can't work normally, be sure to check carefully!

Failure and repair

1, spring damage, pulse valve spring on the spool is easy to damage, the appearance of the pulse valve is a long-term blow to the nozzle, the treatment is to replace the spring.

2, rubber mat damage, after a long time of use, the rubber pad on the pulse valve spool is easy to damage, the appearance is that the pulse valve for a long time to blow air into the nozzle, the treatment is to replace the rubber pad.

3, valve core dirt, because the air intake is not clean, cause the dirt accumulation at the valve core, the appearance is the nozzle long air intake or power pulse valve does not work, the treatment is to clean the valve core.

4. The diaphragm is damaged. After long-term operation, the diaphragm is prone to fatigue and oxidation.

5. The throttle hole is blocked or damaged, and the inlet air is not clean, which will easily lead to the throttle hole blocking. The appearance is that the pulse valve has been blowing air to the nozzle for a long time, and the treatment is to clean the throttle hole. The damage or loss of the throttle orifice makes the throttle orifice lose its interception function, resulting in abnormal pressure relief. The appearance is that the pulse valve ACTS after receiving electricity, and the pressure relief orifice releases air, but the pulse valve does not spray, and the treatment mode is to replace the throttle orifice.

Hope to receive your inquiry,waiting for at anytime


Product Tags:

pneumatic valve diaphragm

      

rubber diaphragm

      
Wholesale High Flow Rate 4 Inch Diaphragm WPS-CA/EP102 For Solenoid Pulse Valve Application Dedusting from china suppliers

High Flow Rate 4 Inch Diaphragm WPS-CA/EP102 For Solenoid Pulse Valve Application Dedusting Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Ningbo Brando Hardware Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)