Brand Name : Brando
Model Number : 1070/4
Certification : CE
Place of Origin : China
MOQ : 50 PCS
Payment Terms : L/C, T/T, Western Union
Supply Ability : 100000 pcs per month
Delivery Time : 7 working days
Packaging Details : inner boxes,cartons,pallets
Screw connections : 1/2"SAE
Power : Solenoid
Media : Refrigerant
Structure : Diaphragm Pilot Operated
Material : Brass
Function : Normally Closed
Voltages : AC110V, AC220V, DC24V
Ambient temperature : -35 - 105 °C
Application : Refrigeration Parts
Refrigerants : R125 R134a R152a R22 R404A R407A R407C
1070/4 1/2'' Inch SAE Flare Diaphragm Pilot Refrigeration Solenoid Valve
1070/4S: 1/2'' Inch SAE Connection Diaphragm Pilot Operated NC Refrigeration Solenoid Valve ODS Connection Without Coil.
1070/4A6: 1/2'' Inch SAE Connection Diaphragm Pilot Operated NC Refrigeration Solenoid Valve ODS Connection With 220/230 VAC(A6) Coil.
1070/4A7: 1/2'' Inch SAE Connection Diaphragm Pilot Operated NC Refrigeration Solenoid Valve ODS Connection With 240 VAC(A7) Coil.
HF2 HF3 HM2 HM3 HM4 CM2 Coil can be mounted on the valve.
Electromagnetic step-by-step direct piston operation structure
①The recoil type special structure which integrates the direct-acting valve opening and the first different valve opening in one;
②The main valve can be opened without pressure, the low-pressure differential flow is large, and the scope of application is wide;
③Using PTFE seal, good temperature resistance;
④Reliable operation with zero pressure difference;
⑤Type: normally closed.
Technical Data:
Dimension:
Replacement Castel Type Solenoid Coil:
Before Installation:
Before connecting the valve to the pipe, it is advisable to make sure that the refrigerating system is clean. In fact, valves with P.T.F.E. gaskets, and particularly piston valves, are sensitive to dirt and debris.
Furthermore, check that the flow direction in the pipe corresponds to the arrow stamped on the valve body. All the valves can be mounted in any position so long as the coil does not point downwards.
The brazing of valves with solder connections should be carried out with care, using a low melting point filler material. It is not necessary to disassemble the valves before brazing, but it is important to avoid direct contact between the torch flame and the valve body, which could be damaged and compromise the proper functioning of the valve.
Before connecting a valve to the electrical system, be sure that the line voltage and frequency correspond to the values marked on the coil.
Focus on your demands, Offer you best solution:
√ Contact us if some points you have doubt
√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for
√ Contact us if you are doing designing
Welcome to your any question and inquiry!
![]() |
1070/4 1/2'' Inch SAE Flare Diaphragm Pilot Refrigeration Solenoid Valve Images |